Peter created an article,
What if I delete my site and unbind my dongle, will I lost all the history data?
Yes, after delete the site, you will lost all the history data.
-
Peter created an article,
Can I use the BMS of T45 battery with the T30 battery?
No, it does not support T30 battery, for T30 battery, you need to use T30 BMS. But you can use it with T63 battery.
-
Peter created an article,
What does the "Self Test" function do?
Primarily for CEI 0-21 compliance (Italy), it tests grid protection functions (over/under voltage/frequency) and reaction times. A report is displayed on the LCD. Requires grid connection.
-
Peter created an article,
What does the "Battery Awaken" function do?
If the battery voltage drops too low (below Discharge Cut for Lead-acid or Min Capacity for Lithium), enabling "Battery Awaken" forces charging from PV or grid (if enabled) to recover the battery. ...
-
Peter created an article,
What size AC cable and breaker are recommended for grid connection for X3-Hybrid G2 inverter?
Recommended cable size is 4-6mm². Recommended breaker sizes are 20A (5.0/6.0kW), 25A (8.0kW), or 32A (10.0kW). Always follow local regulations.
-
Peter created an article,
What is the IP rating and where can X3-Hybrid G2 inverter be installed?
The inverter has an IP65 rating, making it suitable for outdoor installation. Mount on a solid wall (brick/concrete) within ±5° slope, avoiding direct sunlight, rain exposure, and ensuring good ven...
-
Peter created an article,
Is a meter connection mandatory for X3-Hybrid G2 inverter?
Yes, connecting an authorized SolaX meter is mandatory. Failure to do so will result in a "Meter fault" alert and inverter shutdown. It enables export control and whole-house monitoring.
-
Peter created an article,
What is the switchover time to EPS mode during a grid failure for X3-Hybrid G2 inverter?
The switchover time to EPS mode is less than 1.5 seconds.
-
Peter created an article,
What battery types and voltages are compatible with X3-Hybrid G2 inverter?
The inverter works with high-voltage Lithium batteries (160-800V) and Lead-acid batteries (160-500V). Communication compatibility (CAN/RS485) is required for Lithium BMS.
-
Peter created an article,
What is the maximum number of inverters that can be connected in parallel for X3-Hybrid G2 inverter based on on-grid operation?
Up to 10 X3-Hybrid inverters can be connected with eps parallel box in parallel for on-grid operation, with one designated as the "Master".