How can I get the "TokenID" of SolaX API?
Please login your solax cloud web, and follow the steps below:
-
I have a solar system by solax ,I need my firmware updating
Kindly provide us you inverter serial number or pocket dongle number
-
How to check the meter/CT installation is correct or not?
Is there an error on the inverter Set the inverter to OFF modeTurn ON some house loadsCheck the Pgrid value (Press DOWN button on the main screen). If positive, then the meter/CT direction is rever...
-
What is three-phase unbalance function and its benefit?
The three-phase unbalance function is a feature available in SolaX inverters like the X3-Hybrid G4, G4 Pro, X3-IES, and X3-Ultra series. It allows the inverter to independently control power output...
-
What is the Warranty period for SolaX XHub?
Warranty for two years; Over two years, we support paid services
-
How to Enable XSchedule function of the SolaX XHub?
Please follow the steps below:Step 1: Enable the XSchedule function following the operation as follows
-
What is the function of "RST" key for SolaX XHub?
Long press for 3 s to turn on AP for network configuration. Long press for 10 s to reset the system settings for meter, export control and WiFi. Press twice to restart the system.
-
How should the Inverter "BMS" cable be connected to the Parallel Box?
The Inverter "BMS" should be connected to the "BMS" port on the Box (Inverter side).
-
What are the requirements for the number of batteries when using the G2 box?
The number and model of batteries connected to the two strings must be the same.
-
Does the BMS Parallel Box G2 require a BMS connection?
Yes. Unlike the G1 which allowed connection without BMS, the G2 requires the BMS to be connected for the main string. The BMS is indispensable for the main string in the G2 setup.