How many inverters can be paralleled for X3-HYB-G4 Pro?
Up to 5 units without an EPS parallel box; up to 10 units with the box.
-
What is the maximum battery capacity supported for X3-HYB-G4 Pro?
Up to 280.8kWh with HS36 batteries using a TCBox-70.
-
How does the dual battery port work of X3-HYB-G4 Pro?
Dual ports allow flexible battery configurations: 25A per port if connected to separate batteries. 30A for a single battery on one port. 50A total when paralleled via a splitter cable (sold sepa...
-
What are the key features of the X3-HYB-G4 Pro?
The X3-HYB-G4 Pro offers 3 MPP trackers, 20A PV input per MPPT, dual battery ports (50A total current), IP66 protection, AI-driven energy management, V2X/heat pump compatibility, and support for up...
-
Does X3-hybrid G4 inveryter support datahub?
Yes, it supports to connect with datahub.
-
Do I need an external RCD for grid connection of X3-Hybrid G4 Pro inverter?
The inverter has an integrated RCMU. If required locally, use a 300 mA Type-A or Type-B RCD
-
Does the X3-Hybrid G4 Pro inverter comply with CE/RCM/TUV standards?
Yes. Certifications are listed on the nameplate
-
Can I connect a generator to the X3-Hybrid G4 Pro inverter?
Yes, via the COM2 DI/DO terminal. Ensure the generator has an ATS and matches load + charging power
-
Why does the inverter display "Fault & Charging"?
This occurs when grid voltage/frequency is abnormal, but PV continues charging the battery. Check grid parameters
-
I accidentally deleted my site, how to recover my previous data?
We are sorry to say it does support to recover the previous data after this action.