Recent activity by Peter-
Does X3-ULTRA inverter support to connect different types of batteries at the same times?
The X3-ULTRA inverter supports connecting two separate battery strings via its dual battery terminals, but different battery models cannot be mixed within a single string. It only allows expanding ...
-
Does X3-ULTRA inverter support to connect Half wave loads?
The X3-ULTRA inverter supports half-wave loads, such as small household appliances (e.g., hair dryers, decorative lights), during off-grid operation. About more details, please check the user manual.
-
Does X3-Hybrid-G4 pro inverter support to connect Half wave loads?
The X3-Hybrid-G4 Pro inverter supports half-wave loads, provided they do not exceed 2kW during EPS (emergency power supply) operation. This capability ensures compatibility with smaller household d...
-
Does X3-Hybrid-G4 pro inverter support to connect different types of batteries at the same times?
The X3-Hybrid-G4 Pro inverter does not support connecting different types of batteries simultaneously. It requires identical battery models. The two groups must be the same battery model and firmwa...
-
How does the EVC GREEN charging mode prioritize solar energy over grid power?
GREEN mode maximizes solar usage by charging only when surplus PV power exceeds the minimum threshold (3A or 6A). If PV power is insufficient, it either stops charging (6A level) or supplements wit...
-
How do I troubleshoot the "Earth Fault" error?
Check the ground connection of the inverter and PV modules. Ensure proper PE wire installation and insulation integrity. If persistent, contact SolaX support.
-
What maintenance tasks are recommended for the X3-MEGA G2?
Clean fans and vents annually. Check cable connections and grounding. Update firmware periodically. Verify PV module performance and grid stability.
-
What is the recommended installation environment for the X3-MEGA G2?
Ambient temperature: -25°C to +60°C. IP66 protection allows outdoor installation. Ventilated area away from flammable materials.
-
What is the maximum PV input voltage supported by the X3-MEGA G2?
20K-35K models: 800V DC. 40K-60K models: 1100V DC.
-
What maintenance tasks are recommended for the X3-ULTRA?
Clean fans and vents annually. Check cable connections and grounding. Update firmware periodically. Verify battery health and communication.