What is the switchover time to EPS mode during a grid failure for X3-Hybrid G2 inverter?
The switchover time to EPS mode is less than 1.5 seconds.
-
What battery types and voltages are compatible with X3-Hybrid G2 inverter?
The inverter works with high-voltage Lithium batteries (160-800V) and Lead-acid batteries (160-500V). Communication compatibility (CAN/RS485) is required for Lithium BMS.
-
What is the maximum number of inverters that can be connected in parallel for X3-Hybrid G2 inverter based on on-grid operation?
Up to 10 X3-Hybrid inverters can be connected with eps parallel box in parallel for on-grid operation, with one designated as the "Master".
-
What are the key differences between Version E and Version C for X3-Hybrid G2 inverter?
Version E supports Emergency Power Supply (EPS) functionality when an external changeover device is installed, allowing backup power during grid failure. Version C does not have EPS capability.
-
What do the model number suffixes (E, C, D, N) mean for X3-Hybrid G2 inverter?
"E" indicates EPS function is available (requires external changeover device). "C" indicates no EPS function. "D" means the unit has a DC switch. "N" means it does not have a built-in DC switch (ex...
-
Does the X-Smart G1 inverter support battery storage?
The manual does not mention battery compatibility. It is designed for grid-tied PV systems only.
-
Can I use third-party meters?
No. Only SolaX-authorized meters are compatible. Unauthorized meters may cause shutdowns and void warranty.
-
What does "Bus Volt Fault" mean?
DC bus voltage is out of range. Verify PV input voltage and disconnect/reconnect PV strings.
-
How do I set export control for my X1-Smart G1 inverter?
Enable it in Settings > Export Control. A SolaX meter is required to limit grid feed-in (0–20 kW range).
-
How should PV modules be grounded?
Comply with local regulations. SolaX recommends grounding all conductive surfaces of the PV generator.